VENTILATION

DESCRIPTION

We offer the world known Gaylord which manufactures a complete line of commercial kitchen exhaust hoods and associated equipment custom engineered to meet every design and budget requirement.

The CG3, a high efficiency grease extractor with automatic water wash cleaning, offers performance features and benefits not found on any other ventilator in the market.

 
( 1 ) Universal Mounting Bracket
Allows hanging from overhead or bolting to wall.

( 2 ) Built-in 3" Air Space
For compliance with NFPA-96 requirements when mounting to limited combustibles.

( 3 ) Optional Second Water Wash Manifold
For heavy duty applications.

( 4 ) Full Length Hinged Inspection Doors
Provides easy access to all components, including duct fire protection nozzles, for inspection and service.

( 5 ) Three Grease Extraction Baffles
Grease catch?design provides 95% grease extraction performance. Third baffle swings for enhanced access during inspection and service.

( 6 ) Three Position Damper
1. Exhaust Cycle (shown)
2. Wash Cycle (closes forward)
3. Fire Cycle (closes back)
Optional CustomAir™ Baffles-Allows for reduced air volumes over light and medium duty equipment (baffles not illustrated)

( 7 ) Concealed Sloped Gutter
Full length apron conceals sloped gutter and drain fittings providing architecturally "clean" appearance.

( 8 ) Damper At Air Inlet Slot
Will not interfere with duct shafts, building structure, plumbing and mechanical equipment as often experienced with duct collar dampers.

( 9 ) Under Side Access Design
All components accessible from the underside - no need for access through the ventilator or the ceiling.

( 10 ) Heavy Duty Front
All fronts constructed of 16 gauge stainless steel.

( 11 ) All Stainless Steel Construction
Type 304, number 4 finish. No aluminized or galvanized steel - assurance of quality.

( 12 ) Low Profile Design
24" to 30" maximum height allows for use in low ceiling applications with minimal impact on building structure.

( 13 ) Continuous Mounting Bracket
Provides 6" on center hanging points for easier installation.

( 14 ) Fail Safe Electric Damper ControlThermostat activated damper closes to fire cycle position in event of power loss. Resets to normal operating position when fan is restarted.

( 15 ) Duct Collar
Located 6" off back allowing construction of a duct shaft without interfering with the wall and assures easy field welding of the duct connection.

FOR MORE DETAILS OF GAYLORD VENTILATION EQUIPMENT PLEASE CONTACT ITW FEG HONG KONG FOR FURTHER DETAILS. YOU MAY USE THE FOLLOWING LINKS TO VISIT THE WEBSITES FOR OTHER DETAILS :
Gaylord Industries : http://gaylordusa.com/


 
Genial Einfach Genial1

PREMAX TECHNOLOGY

HOBART worldwide

HOBART worldwide

Distributor map

Find your distributor:
 
HOBART ITW FEG HK LTD
Unit 2516, 25F., Technology Park,
18 On Lai Street, Siu Lek Yuen,
Shatin, N.T., Hong Kong
Phone (852) 2341 9315
Fax (852) 2341 3914
Sales@hobart.com.hk